Fire Alarm Voice Evacuation Message Download
‘Prepare for evacuation’ is a continuous constant amplitude signal with varying frequency of 1200Hz to 500Hz over one-second then repeated. This alarm is tone 9 in the E2S alarm sounders, you can listen to the tone here. Edwards Signaling manufacturers a complete line of audible and visual signals for industrial and commercial applications. Products include: fire alarm control panels, flashing and steady LED and halogen beacons and lights, strobes, vibrating horns and bells, outdoor warning sirens, public address and intercom systems, LED message centers and electronic system signals. 519 downloads 2 comments. Evacuation Message and Alarm - mp3 version Evacuation Message and Alarm. A stereo recording of a fire alarm cut to loop. Rode NT-4 FEL. Conventional Voice Evacuation Systems. Small applications such as churches, schools, and theaters sometimes require more than just a basic fire alarm to effectively and safely evacuate occupants. Ambience Fire Evacuation Crowd Alarm Stairwell Stereo 1:02 Sci-Fi Male Voice Announcement: Full Warning Sequence, Evacuation - Long Loop. In NFPA 72, 2010 Edition regarding voice evacuation message content (24.4.2.17.1) in a elementary school it indicates a minimum of 2 cycles preceding and follow the voice message. In Annex A, it states 'Generally, the emergency message should consist of an alert tone of 1 second to 3 seconds, followed by a voice message that is repeated at. Listen To Message 008. Download Message 008. Message 009 Female Voice 'Attention. The fire alarm system has been activated. Please exit the building in a calm orderly manner. Look for the nearest exit sign and leave the building quickly and quietly. Remain outside the building until further notice.' Listen To Message.
- Fire Alarm Voice Evacuation Message Download
- Fire Alarm Voice Evacuation Message Download Pc
- Fire Alarm Voice Evacuation Message Download Free
- Fire Alarm Voice Evacuation Message Download Android
- Fire Alarm Voice Evacuation Message Downloads
TELEFIRE’s TFVE-300 PA system is an integrated and modular 300W PA system that includes emergency messages in Hebrew, standard warning sounds and the option to combine background music and a bell timer system.
The TFVE-300 is an integrated monolithic system, built into a single casing, containing PA system units, a power supply and backup batteries. /speccy-for-mac.html. The system can play recorded alarm and evacuation messages saved in its μSD card, and in addition, allows making announcements through a microphone integrated into the front panel, or via a remote emergency microphone.
The TFVE system includes evacuation messages recorded in accordance with NFPA requirements and additional messages which can be played, based on various scenarios. When an alarm is received from the fire detection system, an evacuation message will be played automatically. Upon the firefighters’ arrival, announcements can be made manually via the integral microphone or via the remote microphone, while prioritizing messages from the microphone. /download-myob-13.html.
The system is approved by the Standard’s Institute of Israel and can be activated by a direct connection to the control panel or by means of the ADR-723 or ADR 823A output assemblies.
The PA system also includes inputs for an uncontrolled microphone used for service purposes, an input for playing background music, contacts for playing general messages and an Ethernet port.
The PA system has been tested and meets the European Standard requirements and the requirements of the Standards Institute of Israel.
Fire Alarm Voice Evacuation Message Download
Below you will find a list of all standard alarm tones availableon E2S alarm horn sounders. Many sounders offer up to 45alarm tones and four stages as standard and bespoke tonescan also be created and factory programmed into the devices.Tone | WAV file | Frequency Description |
---|---|---|
T 1 | 340 Hz Continuous | |
T 2 | 800/1000Hz @ 0.25 sec Alternating | |
T 3 | 500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop | |
T 4 | 800/1000Hz @ 1Hz Sweeping | |
T 5 | 2400Hz Continuous | |
T 6 | 2400/2900Hz @ 7Hz Sweeping | |
T 7 | 2400/2900Hz @ 1Hz Sweeping | |
T 8 | 500/1200/500Hz @ 0.3Hz Sweeping | |
T 9 | 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. | |
T 10 | 2400/2900Hz @ 2Hz Alternating | |
T 11 | 1000Hz @ 1Hz Intermittent | |
T 12 | 800/1000Hz @ 0.875Hz Alternating | |
T 13 | 2400Hz @ 1Hz Intermittent | |
T 14 | 800Hz 0.25sec on, 1 sec off Intermittent | |
T 15 | 800Hz Continuous | |
T 16 | 660Hz 150mS on, 150mS off Intermittent | |
T 17 | 544Hz (100mS)/440Hz (400mS) – NF S 32-001 | |
T 18 | 660Hz 1.8sec on, 1.8sec off Intermittent | |
T 19 | 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 | |
T 20 | 660Hz Continuous | |
T 21 | 554Hz/440Hz @ 1Hz Alternating | |
T 22 | 544Hz @ 0.875 sec. Intermittent | |
T 23 | 800Hz @ 2Hz Intermittent | |
T 24 | 800/1000Hz @ 50Hz Sweeping | |
T 25 | 2400/2900Hz @ 50Hz Sweeping | |
T 26 | Bell | |
T 27 | 554Hz Continuous | |
T 28 | 440Hz Continuous | |
T 29 | 800/1000Hz @ 7Hz Sweeping | |
T 30 | 300Hz Continuous | |
T 31 | 660/1200Hz @ 1Hz Sweeping | |
T 32 | Two T chime. | |
T 33 | 745Hz @ 1Hz Intermittent | |
T 34 | 1000 & 2000Hz @ 0.5 sec Alternating – Singapore | |
T 35 | 420Hz @ 0.625 sec Australian Alert | |
T 36 | 500-1200Hz 3.75sec /0.25sec. Australian EvacuationTone | |
T 37 | 1000Hz Continuous – PFEER Toxic Gas | |
T 38 | 2000Hz Continuous | |
T 39 | 800Hz 0.25sec on, 1 sec off Intermittent | |
T 40 | 544Hz (100mS)/440Hz (400mS) – NF S 32-001 | |
T 41 | Motor Siren – slow rise to 1200 Hz | |
T 42 | Motor Siren – slow rise to 800 Hz | |
T 43 | 1200 Hz Continuous | |
T 44 | Motor Siren – slow rise to 2400 Hz | |
T 45 | 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm |
Hootronic and Belltronic Alarm Tones and Sounds
Additionally, the E2S Hootronic alarm horn soundersfaithfully replicates the sounds made by legacyelectro-mechanical signalling devices.
FTTone | WAV file | Frequency Description. |
---|---|---|
T 1 | Industrial Claxon | |
T 2 | High Frequency Mechanical Siren | |
T 3 | Medium Frequency Mechanical Siren | |
T 4 | Electro Mechanical Buzzer | |
T 5 | Mechanical Bell |
Fire Alarm Voice Evacuation Message Download Pc
Choose a range below to view the products:Listen to Evacuation Alarms Tones and Sounds
Evacuation sirens are used in many applications to provide awarning or notification of approaching danger, for example:tsunami warning, civil defence, tornado alert, toxic leaks,flood warnings and in a range of other emergency situations.
Many countries, such as Australia have a national ’evacuatetone’; the UK however does not. The relevant standard, BS5839-1, merely states that the evacuate tone should containfrequencies within the range 500Hz to 1000Hz. However, forparticular applications, such as offshore use, specific tonesare defined. Known as “/information/pfeer-ukooa-guidelines”>PFEER–Prevention of Fire, Explosion and Emergency Response – as aminimum, there must be provision for three types of alarm onthe installation or platform:
1. ‘Prepare for evacuation’ is a continuous constant amplitudesignal with varying frequency of 1200Hz to 500Hz overone-second then repeated.
This alarm is tone 9 in the E2S alarm sounders, you can listento the tone here:
T 9 | 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. |
2. ‘Toxic gas alarm’ is a constant 1000Hz tone reinforced wherenecessary with a red beacon or strobe.
This alarm is tone 37 in the E2S alarm sounders, you can listento the tone here:
T 37 | 1000Hz Continuous – PFEER Toxic Gas |
Fire Alarm Voice Evacuation Message Download Free
Fire Alarm Voice Evacuation Message Download Android

This alarm is tone 45 in the E2S alarm sounders, you can listento the tone here:
T 45 | 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm |